Kepco MST 488 Programmer Manual de usuario Pagina 67

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 66
MST 488 SVC 013004
C-5
FIGURE C-8. STA — STATUS COMMAND
Syntax: STA
Function: Causes power supply to return operating status to controller.
Description:
This operator commands the power supply to report its present operating status. Status is reported in
the form of a message (character string) as defined below. Any catastrophic error conditions (indicated
by * in the table below) which exist will be reported, until the error condition is corrected. As required
by CIIL, all error messages begin with an ASCII “F” (Fault) followed by a 2 digit code, “07” (Halt). The
code that follows (SCSnn) indicates the type of device and the channel number. The next 3 digit code
describes the nature of the fault: “DEV” for device related errors or “MOD” for non-device errors, such
as syntax.
TABLE C-2. CIIL ERROR MESSAGES
ERROR MESSAGE EXPLANATION
F07 DCSnn DEV Power Loss
The power supply has lost its input power. *
F07 DCSnn DEV Crowbarred
(MAT, MBT) A shutdown occurred due to overvoltage or overcurrent. *
F07 DCSnn DEV Device Turned Off (BOP)
F07 DCSnn DEV Output Fault (MST)
F07 DCSnn DEV Over Temperature
A shutdown occurred due to thermal causes. *
F07 DCSnn DEV Overload
The voltage or current limit point was exceeded. *
F07 DCSnn DEV Voltage Fault
The output voltage is not within limits (voltage mode). *
F07 DCSnn DEV Current Fault
The output current is not within limits (current mode). *
F07 DCSnn DEV Relay Not Opened
The power relay failed to open. *
F07 DCSnn DEV Relay Not Closed
The power relay failed to close. *
F07 DCSnn DEV Polarity Error
The output polarity is not correct. *
F07 DCSnn DEV
Load Path Fault Open or miswired load or error sense leads detected. *
F07 DCSnn MOD Invalid Command
Improper syntax was used. **
F07 DCSnn DEV Not Ready
The output voltage or current has not settled. **
F07 DCSnn DEV Device Not Present
The specified power supply was not present during power up or
during the last DCL. **
F07 DCSnn DEV Device Not Responding
The power supply has failed to communicate to the controller.
**
F07 DCSnn DEV Invalid Voltage Range
The programmed voltage is outside the power supply's range.
**
F07 DCSnn DEV Invalid Current Range
The programmed current is outside the power supply's range.
**
F07 DCSnn DEV Set Modifier Error
An improper SET command was sent. **
F07 DCSnn DEV Invalid Device ID
The selected channel was not between 1-31. **
*Catastrophic error
**Non-Catastrophic error
STA